Stairs.  Entry group.  Materials.  Doors.  Locks.  Design

Stairs. Entry group. Materials. Doors. Locks. Design

» Security and fire control panel “S2000M”: description, technical characteristics and reviews. S2000M monitoring and control panel with two-line LCD indicator Monitoring and control panel S2000M ver 2.05

Security and fire control panel “S2000M”: description, technical characteristics and reviews. S2000M monitoring and control panel with two-line LCD indicator Monitoring and control panel S2000M ver 2.05

It is a development of the "S2000" remote control, maintaining its functions and at the same time having new capabilities. The device is intended for use as part of a security and fire alarm together with control and control devices "Signal-20", "Signal-20P", "S2000-4", "Signal-20" series 02, two-wire line controllers "S2000-KDL", control and control devices for firefighters "S2000" -ASPT", relay units "S2000-SP1", and "S2000-KPB", keyboards "S2000-K" and "S2000-KS", display units "S2000-BI", access control controllers "S2000-2".

Additional features:

  • New housing with a large liquid crystal display that is highly informative (2 lines of 16 characters each). There are functional LED indicators“ALARM”, “FIRE”, “FAULT”, “EMERGENCY”, displaying the state of the object;
  • The number of sections and alarm loops that can be included in these sections has increased, which allows the use of this remote control at larger facilities.
  • The maximum number of user passwords has increased;
  • Sections can be combined into groups. This allows for easier group control of arming and disarming. Any section can be included in several groups;
  • The ability to assign text names not only to sections and users, but also to groups of sections and alarm loops. The text title can be up to 16 characters long;
  • Ability to change the names of messages from alarm loops. For each alarm loop added to the remote control database, you can set 32 ​​custom renaming scenarios. Each scenario allows you to set new text names and display type for any 4 standard messages on the device alarm loop;
  • The console is configured by the "Database Administrator" program from the "Orion Pro" workstation or by the "pprog.exe" utility version 2.00 and higher.

Specifications

  • The number of devices connected to the RS-485 output is up to 127;
  • Number of sections - up to 511;
  • Number of partition groups - up to 128;
  • The number of alarm loops that can be combined into sections is up to 2048;
  • Number of user passwords up to 1023;
  • The number of automatically controlled relay outputs is up to 256;
  • Quantity " entrance zones" - up to 32;
  • Number of users - up to 2047;
  • The volume of the ring event buffer is up to 1023 messages;
  • RS-485 interface line length up to 4000 m;
  • The length of the RS-232 interface line for communication with the printer is up to 20 m;
  • Power supply - from a redundant DC source (for example, "RIP-12" or "RIP-24");
  • Supply voltage range - from 10.2 to 28.4 V;
  • Typical current consumption is 70 mA at a supply voltage of 12 V or 35 mA at a supply voltage of 24 V;
  • Operating temperature range - from 0 to +40 °C;
  • Weight - no more than 0.3 kg;
  • Overall dimensions - 140x114x25 mm.

Monitoring and control panel with two-line LCD indicator, number of sections - 511, loops (zones) - 2048 (S2000M / C2000M remote control)

The security and fire control panel “S2000M” (hereinafter referred to as the panel) is designed to work as part of an addressable system security and fire alarm system and control of fire fighting equipment. Together with ISO “Orion” devices, it can perform the functions of a block-modular security and fire alarm control device, a control device for light, sound and voice warning, gas, powder aerosol and water fire extinguishing, smoke protection, building engineering systems. Information interaction between the blocks is carried out via a wired RS485 communication line. The functions of the device can be expanded by connecting additional units.

Key Features:

  • Indication of the “Alarm”, “Fire”, “Start”, “Stop”, “Fault”, “Disabled” modes. Ability to view individual zones (sections) and system elements that have these states, with display on a symbolic indicator. Sound signaling of alarms, fires, starts and malfunctions on the built-in sound signaling device. Indication of the status of security zones, fire-fighting equipment and other actuators on the blocks "S2000-BI", "S2000-BKI", "S2000-PT", "Potok-BKI"
  • Automatic control of light and sound warning devices, smoke protection, engineering equipment, outputs for transmitting signals “Alarm”, “Fire”, “Start” and “Fault” using control and starting and signal and starting blocks, receiving and control blocks. Automatic start and stop of devices voice notification"Mouthpiece" series. Automatic control of operating modes of the access control and management subsystem to unblock escape routes in case of fire.
  • Manual control from the remote control keyboard and display units:
  • control of security and fire alarm operating modes: arming, disarming, resetting alarms, disabling detectors and actuators (only those controlled by the remote control);
  • manual start and stop of light, sound and voice warning systems, smoke protection, and engineering equipment;
  • control of "S2000-ASPT" devices using "S2000-PT" units: manual start and stop of the fire extinguishing installation, suspension of the start delay and immediate start without delay, selection of automatic or manual control mode for the fire extinguishing installation, alarm reset;
  • control of Potok-3N devices using Potok-BKI units: manual start and stop of the fire extinguishing installation, selection of automatic or manual installation control mode
  • Possibility of connecting to the Orion Pro automated workstation to expand the capabilities of monitoring the status of the protected object and control
  • Possibility of transmitting notifications to the security console using communication blocks "S2000-IT", "UO-4S", "S2000-PGE" and "S2000-PP". Possibility of connecting the ATS100 radio transmitter of the LARS radio security system, RS-202TD of the "Reef String 202" ("LONTA 202") radio security system or TRX-150 for transmitting notifications via radio channel
  • Event log with the ability to view it on the remote control screen and print it on a printer with a serial RS-232 interface
  • Configuring the remote control in the program "Pprog.exe"

Specifications:

PARAMETER NAME

PARAMETER VALUE

Number of ISO “Orion” instruments and devices connected to the RS-485 line, no more

RS-485 interface

Length of RS-485 communication line, no more

RS-232 interface

Number of devices connected to the RS-232 output

1
(computer with workstation, printer, radio transmitter ATS100 or TRX-150 (via converter) or radio transmitter RS-202TD)

Length of RS-232 communication line, no more

Number of alarm loops and addressable detectors grouped into sections, no more

Number of automatically controlled relay outputs, no more

Number of sections, no more

Number of partition groups, no more

Number of user passwords, no more

Event log volume

LCD indicator

2 lines x 16 characters, backlit

from a redundant DC source

Supply voltage

10.2 to 28.4 V

Average current consumption in standby mode

at supply voltage 12 V

at supply voltage 24 V

Maximum current consumption in alarm mode

at supply voltage 12 V

at supply voltage 24 V

Operating temperature range

from minus 10 to +55 °C

Shell protection degree

IP30 (when mounted on a wall)

Weight, no more

dimensions

140x114x25 mm

Type of connection to the device

screw terminal block, wire from 0.2 to 1.5 sq. mm

Installation method

wall-mounted

Equipment consultations New question

Ask a specialist a question about the S2000M monitoring and control panel with a two-line LCD indicator

Question from: Evgeniy

Hello, what version of remote control do you provide?

  • Answered by: Boris Kuzmin Hello. 4.12
  • Purpose:
    is designed for information integration of ISO “Orion” devices in order to organize a single control center and collect system messages, combine alarm loops into sections, create cross connections between sections and outputs of different devices, and expand information display capabilities.
    Interaction between the S2000M console and ISO Orion devices occurs via the RS-485 interface with information transmitted in the Orion protocol.

    Main characteristics:
    Provides display of system messages on a character liquid crystal screen and their storage in a non-volatile buffer (archive) with the ability to view. Controls the display of section states on the “S2000-BI”, “S2000-BKI” and “S2000-BI” display blocks. 01. For better perception of messages, it is possible to specify text descriptions of sections, alarm loops, addressable detectors and users.
    Allows you to manage sections (arm and disarm) using a PIN code on the remote control itself or on the S2000-K and S2000-KS keyboards, Touch Memory keys or Proximity cards from any device that has an input for connecting a reader , from S2000-BKI units, SMS messages via UO-4S.
    Allows you to remotely control the S2000-ASPT and Potok-3N devices using commands from the remote control and from the S2000-PT display units: select automatic or manual control mode for fire extinguishing installations, initiate their launch and cancel the launch. Controls the display of the states of fire extinguishing zones on the “S2000-PT” and the states of the water fire extinguishing installation on the “S2000-BI” version. 01.
    Provides differentiation of user access rights to management functions.
    It has the function of automatically controlling the outputs of control panels, starting and relay units according to 45 different programs.
    Supports control scenarios for outputs, voice announcements, alarm loops and access modes. Output control scenarios allow you to create your own programs for controlling actuators. Scenarios for controlling voice notification allow you to control voice notification devices of the "High-horn" series and can be used for synchronous notification and with the division of an object into zones. Access mode control scripts are designed to automatically open doors along escape routes in case of fire. Loop control scenarios can be used to automatically control alarm loops (for arming or disarming) or operating modes of the S2000-ASPT and Potok-3N devices based on system events.
    Supports connection to Orion workstation or Orion Pro workstation to increase functionality and system expansion.
    It has the ability to connect a printer with a serial RS-232 interface for documenting events or a PC with AWP “S2000” software for displaying events, states of sections and alarm loops.
    Ensures the transmission of notifications by the S2000-IT, UO-4S, UO-Orion and S2000-PP devices. It has the ability to connect the ATS100 radio transmitter of the LARS security radio system or the RS-202TD radio transmitter of the Reef String 202 (“LONTA 202”) security radio system for transmitting notifications over the radio channel.
    Configuring the console in the “Pprog.exe” program or in the program module Database Administrator of the Orion Pro automated workplace.

    Buy Bolide S2000M from Layta at an attractive price. Car S2000M: description, characteristics, customer reviews, photographs and related products..

    Price: 6,665.00 rub.

    Description

    Monitoring and control panel with two-line LCD indicator, number of controlled sections - 511, number of controlled groups of sections 128, number of controlled zones 2048, supply voltage 10.2...28.4 V, current consumption 60 mA, real-time clock battery CR2032, degree IP30 shell protection, operating temperature range -10...+55°С, overall dimensions 140x114x25 mm

    Purpose

    The fire-security monitoring and control panel “S2000M” is designed to work as part of an addressable fire-security alarm system and control of fire-fighting equipment. Together with ISO “Orion” devices, it can perform the functions of a block-modular security and fire alarm control device, a control device for light, sound and voice warning, gas, powder aerosol and water fire extinguishing, smoke protection, and building engineering systems. Information interaction between the blocks is carried out via a wired RS-485 communication line. The functions of the device can be expanded by connecting additional units.

    Specifications

    • Number of connected devices 127
    • Number of supported partitions 511
    • Number of supported partition groups 128
    • Maximum number of input circuits of devices controlled by the remote control 2048
    • Number of user passwords 2047
    • Maximum number of device outputs controlled by remote control 256
    • Event buffer capacity 8000
    • Supply voltage, V:
    • - from external source nutrition 10.2…28.4
    • Current consumption in standby mode, mA, no more:
    • - with a supply voltage of 12 V 60
    • - with a supply voltage of 24 V 35
    • Communication line length via RS-485, m, no more 3000
    • Protection degree IP30
    • Operating temperature range, °C-10…+55
    • Overall dimensions of the remote control, mm 140x114x25
    • Weight, no more, kg 0.3

    Peculiarities

    Indication of the “Alarm”, “Fire”, “Start”, “Stop”, “Fault”, “Disabled” modes. Ability to view individual zones (sections) and system elements that have these states, with display on a symbolic indicator. Sound signaling of alarms, fires, starts and malfunctions on the built-in sound signaling device. Indication of the status of security zones, fire-fighting equipment and other actuators on the blocks “S2000-BI”, “S2000-BKI”, “S2000-PT”, “Potok-BKI”
    Automatic control of light and sound warning devices, smoke protection, engineering equipment, alarm, fire, start and fault signal transmission outputs using control and start and signal and start units, receiving and control units. Automatic start and stop of voice alarm devices of the "Horn" series. Automatic control of operating modes of the access control and management subsystem to unblock escape routes in case of fire.
    Manual control from the remote control keyboard and display units:
    control of security and fire alarm operating modes: arming, disarming, resetting alarms, disabling detectors and actuators (only those controlled by the remote control);
    manual start and stop of light, sound and voice warning systems, smoke protection, and engineering equipment;
    control of “S2000-ASPT” devices using “S2000-PT” units: manual start and stop of the fire extinguishing installation, suspension of the start delay and immediate start without delay, selection of automatic or manual control mode for the fire extinguishing installation, alarm reset;
    control of Potok-3N devices using Potok-BKI units: manual start and stop of the fire extinguishing installation, selection of automatic or manual installation control mode
    Possibility of connecting to the Orion Pro automated workstation to expand the capabilities of monitoring the status of the protected object and control
    Possibility of transmitting notifications to the security console using communication blocks “S2000-IT”, “UO-4S”, “S2000-PGE” and “S2000-PP”. Possibility of connecting the ATS100 radio transmitter of the LARS radio security system, RS-202TD of the "Reef String 202" ("LONTA 202") radio security system or TRX-150 for transmitting notifications via radio channel
    Event log with the ability to view it on the remote control screen and print it on a printer with a serial RS-232 interface
    Configuring the remote control in the program "Pprog.exe"

    Where to buy S2000 in Tyumen at the best price?

    The monitoring and control panel is used as one of the elements included in the fire and burglar alarm. The device is designed to monitor the situation at objects, as well as collect data and indicate an alarm. Thanks to the remote control, all devices are combined into a single system and interact smoothly with each other. All changes that occur, for example, arming or disarming an object, messages about fires or malfunctions, are reflected on the display.

    The MAYAK - Security Systems company offers to buy the S2000 in Tyumen. The goal of the company’s specialists is to promptly provide customers with necessary equipment. To do this, employees of MAYAK - Security Systems monitor new products and study the market security equipment, and also optimize work in order to organize the supply of products to as soon as possible and without delay.

    You can check prices for devices from company employees. Having purchased the S2000 KDL from the MAYAK - Security Systems company, you can be sure that the cost of the product and its quality will be in the optimal ratio.

    The company’s specialists will be happy to answer your questions and help you calculate the cost of your purchase. In order to get professional advice and order the necessary devices, please contact the phone numbers listed on the website.

    We are sure that now you have no doubt where to buy a C2000 in Tyumen at an attractive price!

    The S2000M monitoring and control panel is one of the main devices used in the construction of fire safety systems based on ISO Orion. It connects all system devices via RS-485, receives signals, controls, displays all system information on the display and records it in the event log, and much more.

    According to the structure, all ISO Orion devices are distributed into 3 levels. S200M is located on the second, since it performs the functions of coordinating the upper software and lower hardware levels, as well as organizing network interaction between them. Simply put, the device receives signals from the lower level, processes them and transmits them to the upper level and vice versa.

    ISO levels "Orion"

    It is possible to build systems based on the S200-M monitoring and control panel of varying complexity and configurations, some of which we will look at below.

    IN in this case S2000M allows you to combine several separate systems with their own monitoring and control devices into a single network, which makes it possible to monitor and control each of the systems from a single dispatch center or fire station. Since the devices are connected via the RS-485 interface, they can be located on considerable distance from each other. For greater clarity, the system also uses an indication block that displays all changes and events in the systems, as well as a control and indication block that allows remote control zones and sections. All these actions are controlled by the C 2000M remote control.

    In addition, the remote control can be used when it is necessary to expand existing systems, when one control panel is no longer enough, or when connecting any additional units is required.

    Such a system is built using the addressable threshold control panel Signal-10, integrated with the S2000M remote control and other units of the system via the RS-485 interface. The remote control performs all of the above functions, and also allows you to arm/disarm the addressable threshold loops of the Signal-10 PPKP.

    The addressable analog system is the most complex and functional, since it allows you to determine the location of the alarm with an accuracy of the detector. In this case, the S2000M interacts with the S200-KDL controller, as well as organizes communication between all system devices via RS-485 and its transmission to the Orion/Orion-Pro workstation.

    Interaction of the S2000M with the Orion or Orion Pro workstation is possible in 2 modes:

    1. Computer mode

    This mode involves the joint operation of the S2000M remote control and a PC. The remote control is always on and polls all system devices, while the PC polls only the remote control to obtain information. The main advantages of this mode are the ability to freely control devices from the remote control when the PC is turned on, the absence of switching control between the PC and the remote control, as well as unloading the PC due to the performance of many functions by the S2000M remote control.

    2. “PI/Reserve” mode

    This mode involves constant control of system devices using a PC. In this case, the S2000M remote control is in reserve and comes into operation when the PC is turned off. After the Orion workstation has been restored, the console again goes into standby mode. This control method is used quite rarely and is not recommended for use in security and fire protection systems. It can be used exclusively in cases where the functionality of the workstation is limited by the console, or for Orion workstations of older versions that do not support the “Computer” mode.

    Connection diagram for the S2000M monitoring and control panel