Adjustment sectional doors Doing it yourself is becoming a frequent item that arouses the curiosity of garage owners, since compared to other designs, this type of gate is characterized by greater complexity of the mechanism and is more difficult to configure independently. Before choosing such a structure, the owner of the garage or other premises for which it is purchased must carefully study how to install such structures and adjust their progress, as well as in what ways the adjustment is carried out.
Spring mechanism, which will need to be adjusted
The answer to the question of how to adjust an automatic garage door often lies in working with the cable included in the structure. It is very important to monitor the tension of this element. When a cable becomes tangled or changes configuration, it can lead to incorrect operation or deactivation of the entire system. You can make this adjustment yourself, without hiring professional workers from outside.
Adjustments may be required due to different cases- either self installation this mechanism or significant mistakes made by the craftsmen. Pay attention to the following aspects:
Checking and adjusting the cables is a top priority when working with a sectional structure, because even a small degree of sagging triggers the process of deformation of the guides and the gate itself. It is necessary to check regularly and, if deviations are detected, begin adjustment work.
What should you pay attention to when assessing the condition of the cables? These elements must be evenly fixed and must not fly off, break off or change position. If any deviations are found, you can usually correct them yourself. They do this in the following way:
If these measures are not enough, it is permissible to simultaneously change the position of the shafts located on both sides. In this case, the shafts open and then the one that shows the weaker result begins to rotate. During the torsion of the first shaft, it is necessary to ensure that the second one is at rest. Then the shafts are rotated simultaneously and secured in the desired position.
To adjust this design, perform next sequence operations:
There is an option when the cables located on both sides are not tightened equally. What to do in this case? There is an option to rotate both rollers:
If the garage door has this design, the adjustment procedure will take on a different look. The sequence of work will look like this:
Upon completion of the procedure, it is necessary to check the elimination of sagging and the smooth movement of the door leaf. If a single application of the procedure was not enough, it must be repeated again. This design is not simple, and the cable easily takes the non-working position, so desired result may not be achieved immediately.
When working with gates lifting structure The following procedure must be followed:
If this method did not give the desired result, you can work with this method:
Now you need to check the gate - it should function as expected. Regular carrying out of such work increases the service life of the structure.
This manufacturing company of enclosing structures is the oldest manufacturer in Russia of the described category of gates, so buyers of its products are often interested in how to tension the cable on Dorkhan gates - in particular, those models that are equipped electric drive. Carrying out such an adjustment is a fairly standard procedure and is performed according to a scenario similar to similar procedures for gates of other brands. It should be taken into account that in some Dorkhan models chains are used instead of cables, but otherwise the mechanism of action of the structures is identical and is not burdened with specific problems. To adjust, follow the following algorithm:
If you have purchased a gate design from the manufacturer Dorhan, you should not forget that this company is the largest manufacturer in the country of a wide range of components and spare parts for the production of gates, and the parts that you will use in repair work should, if possible, also be produced by this company . There have been many recorded cases where the use of unsuitable components caused major problems during the operation of the gate and contributed to its premature wear.
Like other gate models, the works of this company come with a solid shaft and a split shaft. To tighten the cable, you must follow the recommendations described in the general case for these types of rollers. For split structures, the previously described mutual rotation of the rollers located on both sides is also suitable.
The issue of adjusting this element of this design is extremely important for the reason that the functioning of the gate equipped with this mechanism greatly depends on this element. A properly adjusted spring will help resist sagging cables and premature wear of the structure protecting a garage or other building for utility or other purposes.
Adjusting the closing and opening of the structure is quite simple and can be easily done with your own hands without the involvement of a specialist. The whole point here is in the special bolts that come with the gate and can be screwed in and out. If necessary, you can buy such bolts at a specialized store.
To work with the spring, you need to reduce the tension of the bolts, and then start turning the roller that is located on the side where the hanging elements were formed in the position of the cable. Then the bolts need to be tightened back.
In order for this type of gate to serve you as long as possible, you must remember to carry out preventive examination and tightening up sagging areas. In addition, it is advisable to carry out maintenance measures - clean the products from dirt with a soft cloth and clean elements that have been corroded. Then the structure will serve reliably and for a long time.
In contact with
Comments
Unfortunately, there are no comments or reviews yet, but you can leave your...
New articles
New comments
S.A.Grade
SvetlanaGrade
SergeyGrade
SergeyGrade
AlexeiThis technique is for gates with a spring, torsion mechanism, which is located above the gate opening. For correct and trouble-free operation of sectional doors, it is necessary to periodically carry out technical inspection and lubrication of moving parts.
With absence Maintenance gate, safety elements, such as a photocell, sometimes cases arise when the gate runs into mechanical obstacles when lowering. Mechanical obstacles mean any objects accidentally left in the gate opening. The consequence of a collision, as a special case, is different tension of the cables.
Possible typical manifestations of misalignment of sectional doors with a manual chain drive or motor:
Typical design of a torsion shaft assembly. Single-shaft system for balancing garage and industrial door leaves. Split shaft.
As a result, the balancing cables for sectional doors fly off or get tangled.
Let's try to figure out how to regulate this nuisance.
Your gate cables and rollers got tangled, flew off, broke, the brackets are still in place. This technique is also applicable when cables are skewed.
First of all, when starting the adjustment, we unlock the engine (if the control is automatic), if it is chain control, we unlock the chain.
We completely weaken the traction spring.
The next step is spring tension.
With the spring weakened, we were able to remove the lower cable thimble. Next we untangle the cable. Having untangled the cable, we throw the cable into the groove of the drum, at least 1/4 of the drum. Next, we lay the cable behind the rollers. We attach the cable loop to the thimble depending on the design of your gate.
Rotate the shaft until the slack in the cables is taken out. To ensure tension of the cables, wind the springs by 1.5 - 2 turns and fix them in this position by tightening the bolts of the tension tips.
If one of the cables still sags, the sagging is eliminated due to the mutual rotation of the shafts, which is ensured by the design of the coupling (the presence of grooved holes for tightening screws).
.To do this, loosen the coupling coupling bolts, rotate the shaft on the side of which there is sagging, while holding the other shaft in its original position.
After eliminating the slack in the cable, tighten the coupling bolts.
The next step is to fully cock the springs in accordance with the recommendation. The number of turns must be indicated on the gate nameplate.
The torsion spring is responsible for balancing the door leaf.
It distributes all the weight evenly, thereby making it easier to lift the gate. Serves as a counterweight. The force of the spring is directed upward, and the mass of the gate is directed downward. The ideal setting of the door leaf is set according to the method recommended by the manufacturer. Data on the number of turns of spring tension is indicated in the product passport, on the gate nameplate, and is available from the gate supplier.
Checking the correct spring tension.
The spring sags a little in the middle - this is its normal charged state. The number of marks on the skein must correspond to the number of revolutions indicated in the passport for the set.
Variants of torsion spring state.
External signs of the spring indicate that it is overtightened.
If you hear clicks or grinding sounds from the spring when the gate is operating, the torsion mechanism must be lubricated with liquid lubricant; if the sound does not stop, you should call a specialist. Check the condition of the spring before the season change, and especially after severe frosts, the spring should sag a little in the middle - the main recommendation
After adjusting the springs, it is necessary to check the correct setting of the sectional door's balancing mechanism.
To do this, you need to lift and then lower the sectional door by hand. The applied force should be 10-20 kg. The gate movement must stop when the force is removed.
What does it mean not a split shaft - it does not have a coupling. A consequence of the lack of parts is that the tension of the cables is adjusted not from the top, but from the bottom. The coupling, as described above, eliminates uneven sagging of the left and right cables.
Complete setup of electric ceiling drive garage doors includes
Instructions for setting the end positions of the sectional-750 (SE-1200; Fast-750) electric drive blade
1_ Setting the upper end position of the garage door
Press and hold the “P” key until “1” lights up. Next, release and press “P” again, “1” will start flashing.
2_ Setting the lower position of the garage door leaf
Press and hold the “P” key until “1” lights up.
The final preservation of the upper and lower position of the garage door leaf:
By pressing the "+" key we set the number "1" on the display. Next, press the “P” key for 5 seconds. "0" appears on the display.
The programming is completely saved and completed.
SETTING UP THE REMOTE
Instructions for setting up the DorHan remote control for the Sectional-750 (SE-1200; Fast-750) ceiling drive
On the display of the electric drive, press and hold the R button. Another zero should appear for a second and go out.
After that, select the desired button on the remote control and press it twice. The remote is programmed!
VIDEO INSTRUCTION
Programming the remote control SE-750 (SE-1200); Adjustment of the upper, lower position and force of the gate.
WE CONFIGURE SLIDING AUTOMATIC GATES
Instructions for setting up the DorHan remote control for the drive sliding gates Sliding 800 (SL-300; SL-1300; SL-2100)
1.Hold down the programming key for the electric drive board.
The indicator should flash.
Release the key and press the button on the DorHan remote control (2 times) that you chose to open the device.
The remote control recording is finished.
VIDEO INSTRUCTION
Programming the remote control Sl-300 (Sl-800; Sl-1300; Sl-2100) new drive board; Drive board without protective casing.
DOWNLOAD INSTRUCTIONS ELECTRIC DRIVE DOORHAN SECTIONAL-750 PDF file format
If you have sectional doors installed in your garage, then you will certainly be interested in the question of adjusting automatic garage doors yourself. After all, everyone knows that professional craftsmen charge a hefty price for such work, and every good owner wants to save money. Also, calling a specialist will waste your precious time, which is an unaffordable luxury these days.The cables and their tension level are important in the entire design of such gates. The service life of your gate depends on them. They are intended to activate the workflow , and also to balance the balance. If you are the owner of just such a gate, then you should not allow the cables to sag.
Any owner who is concerned about the quality of his garage door mechanism can handle this type of work. All you need is to understand how to do it. To do this, we suggest that you watch the video presented at the end of the article.
Figure 1: main design elements of sectional doors
Figure 2: components of a sectional door
But very often, after installing the entire structure itself, you may have a question: how to adjust Doorhan gates with an electric drive? It is quite simple to adjust Dorhan sectional doors yourself; you only need to follow our instructions.
If you are interested in how to tension a cable (chain) on a large garage door made by Dorhan or another similar company, follow the instructions:
Carrying out renovation work in this scenario, you will be able to maintain your garage door in the same condition as purchased for many, many years. Still, from time to time it is worth checking the tension in the cables, as it can weaken without giving a visible effect. And, as you know, any breakdown, like a disease, is better to prevent than to treat.
Figure 3: Drive device
In the process of adjusting the lever gate mechanism, the most popular question among our customers is: self-adjustment automatic gate springs.
Correct spring tension on sectional doors allows you to avoid sagging cables, and, consequently, unplanned wear and tear on the entire garage door mechanism. This adjustment of the opening and closing of automatic sectional doors is quite simple by unscrewing and tightening the bolts.
Therefore, if you are interested in how to properly tension the spring on a sectional door, for example, manufactured by Dorhan, or a similar design, then to do this, you should ease the tension on the bolts and then turn the shaft from the side where the cable slack occurred. And then you should tighten the bolts back. This method is universal and works flawlessly.
Video: Adjusting automatic garage doors Video: Tensioning a spring on a sectional door
Every good owner knows that any mechanism, even the most reliable one, can break down. And to prevent any unpleasant surprises, we recommend inspecting your garage door mechanism at least once a month for possible problems.
The most common problem with garage doors during their constant use is sagging of the cable, which is responsible for raising and lowering the garage door. This occurs due to improper installation of springs on sectional doors.
First of all, we would like to draw your attention to the fact that adjusting or replacing the cable of sectional doors is unsafe, since the torsion springs are under high tension. Therefore, perform this work with great care and use only reliable and high-quality tools.
Here are the main stages of work:
The installation of the torsion spring mechanism of Dorhan sectional doors is carried out according to a similar principle. If you still cannot adjust the tension of the sectional door cables, then our advice is to seek the services of qualified repairmen.
Figure 2: Basic parameters of torsion springs
Figure 3: Spring Tension Steps