Stairs.  Entry group.  Materials.  Doors.  Locks.  Design

Stairs. Entry group. Materials. Doors. Locks. Design

» A sewer riser in a private house without access to the roof or with an entrance and whether it is needed at all. Fan pipe: nuances of installation and connection The size of the drain pipe for a country house

A sewer riser in a private house without access to the roof or with an entrance and whether it is needed at all. Fan pipe: nuances of installation and connection The size of the drain pipe for a country house

Installation of independent or centralized system Disposal of wastewater is impossible without installing a special drainage system. The element blocks the return flow of gases into the bathrooms, acting as a connecting component between the septic tank and the atmosphere.

The technology for installing the riser is quite simple. But before you start work, you need to understand the principle of operation of the ventilation duct and understand how to properly install the vent pipe in the house. The answers to these questions are described in detail in the article.

The fan pipe is structural element, which connects the pipeline to a specially constructed ventilation duct. Its key purpose is to remove gases and odors from the sewer system.

The presence of a ventilation riser in the system ensures that there are no unpleasant loud sounds in living quarters that occur when water is drained, and the “fragrance” of sewage sewage (+)

The length and shape of this element can be arbitrary. There are models of vertical and horizontal design, beveled at right or acute angles.

The principle of operation of the vent pipe is simple. Wastewater entering vertical riser, create a vacuum in the pipeline cavity. It can be partially compensated by water, which acts as a hydraulic damper in the siphons of installed plumbing fixtures.

But if the vertically installed riser has a large length and at some point there is a one-time powerful discharge of waste liquid, then a vacuum arises in the sewer pipe.

The formed piston from the liquid with all its strength and characteristic “smacking” sound at one moment tears off and breaks through the hydraulic dampers of the plumbing, emptying the siphons.

As a result, water is completely sucked out of all water seals. Therefore, there are no obstacles left. Due to this, they quickly spread throughout the building.

This effect also occurs during rapid pumping. fecal pump content cesspool or a septic tank into the tank of a sewer truck

The trouble is that the appearance of an unpleasant “fragrance” in living rooms the matter is not limited. The natural process of decomposition of feces is accompanied by the release of gases harmful to households: methane and hydrogen sulfide.

If the system is equipped with a fan riser, at the moment of “throwing in” there are no such consequences, since the vacuum created in the collector simply does not have time to break through the hydraulic valves in the siphons.

This is prevented by flows of atmospheric air, which, simultaneously with the occurrence of vacuum, are drawn into the system, blocking the penetration of gases into the room when draining and pumping out the septic tank.

Image gallery

When installing a drain pipe with a cross-section of 110 mm, the connection check valve performed using an adapter.

One of the ways to install a check valve in the cavity of a waste pipe and then connect it to the sewer outlets of the system

An important point: all operations for installing a vent pipe should be carried out on dry surfaces. At the stage of fixing the check valve, you should not use silicone sealants or any kind of lubricant.

Typical installation errors

Most often, the situation with the formation of a vacuum in the system occurs when pipes of different diameters are used in its arrangement. For example: the toilet is connected to a pipe D 110 mm, the bathtub is connected to a pipe D 50 mm, and the hole cistern– D 70 mm.

Unpleasant stench in bathrooms often appears when plumbing fixtures are equipped with siphons that have insufficient volume. This occurs due to the fact that when the devices are not used regularly, the remaining water in the siphons dries out, removing the hydraulic valve and opening up free access to the spread of “aromas”.

By correctly calculating the dimensions of the drain pipe and installing it in compliance with all installation rules, you can almost completely eliminate the possibility of accumulation and the likelihood of sewer gases entering the house. And then problems with the operation of the sewer system will definitely not arise.

Do you have practical skills in installing a ventilation drain pipe? Share your accumulated knowledge or ask questions on the topic - the contact block is located below.

Before we talk about vent pipes, you need to find out whether a vent pipe is needed in a private home. The purpose of the drain pipes is simple to explain - they are needed to connect the sewage system to the atmosphere, thereby ensuring ventilation of the system. In addition, the drain pipe equalizes the pressure in the sewerage pipeline, so the resulting vacuum does not lead to emptying of the siphons.

The need to install waste pipes directly depends on the volume of simultaneous discharge into the sewer - if it is large enough, then a pipe is definitely needed. However, this point will be discussed further. In this article we will talk about why a drain pipe is needed in the sewer system of a private house.

Functions of the drain pipe

There is always air present in any sewer pipeline, but when drained, it begins to escape into the atmosphere and draws water from the water seals. The absence of a water seal always causes the characteristic sewer smell to enter the room.

A drain pipe in a private house simultaneously serves three purposes:

  • Removing gas from sewer system pipes;
  • Maintaining the required pressure in the pipes, which allows simultaneous drainage a large number of wastewater without the risk of releasing an unpleasant odor into the house;
  • Forms the necessary vacuum in the sewer system.


It is mandatory to install a drain pipe if the following conditions are met:

  • The diameter of the sewer riser is less than 50 mm;
  • Each floor has a separate bathroom connected to a single sewer system;
  • Water from the connected pool is drained into the sewer;
  • There is an autonomous sewage system (for example, a septic tank) right next to the building.

Installation of sewerage pipes

When installing a vent pipe in a private house, you need to ensure that the following rules are followed:

  • The diameter of the fan pipe must always match the dimensions of the riser;
  • The drain pipe and ventilation from the sewer pipes are led to the roof so that it is located at the maximum distance from windows and balconies;
  • It is best to place the fan pipe at a distance of 30-50 cm from the ridge - as practice shows, this height is enough for normal removal of air from the system;
  • Fan pipes are installed to compensate for one-time drains, so their value must be known exactly before putting the system into operation;
  • For the bathroom, a 110 mm riser is used, so the pipe diameter cannot be less than 110 mm;
  • For bathroom drainage, 50mm pipes are usually used, and the drainage pipe must have the same capacity.

Rules for installing vent pipes

When installing a system with a drain pipe connection, the following rules must be observed:

  • When selecting material for a drain pipe, you need to ensure that the diameter of the selected pipes matches the diameter of the riser;
  • The upper edge of the vent pipe should be at the point where the released air will most quickly mix with the atmosphere (for example, an attic is not suitable for this);
  • The first segments of the sewer system must be located in the heated part of the room;
  • The last section of the pipeline is installed where there is no heating - the movement of polluted air masses is ensured by temperature changes and pressure changes.


There is one more point that is worth considering separately, since it is not directly related to drainage pipes, but directly relates to the operation of the sewerage system. When installing various plumbing fixtures, the following situation arises - the volume of siphons does not correspond to the characteristics of the plumbing fixtures.

All this leads to simple result: in small siphons, the water dries out too quickly, and nothing prevents the smell from entering the room, and draining from large siphons is impractical, and drain pipes are likely to simply not be able to compensate for it.

Exiting ventilation pipes to the roof

The sewer system is used to transport wastewater outside the building. In order for the sewer system to function fully, it must be equipped with ventilation - and for this, risers with vent pipes are installed. An important point: fan pipes for external sewerage cannot be equipped with various exhaust devices, such as deflectors or weather vanes.

If there are several risers in the building, it will be much easier to combine them into one system and remove them through one ventilation duct ending in a drain pipe. The design provides for the sequential installation of an oblique tee, a 45-degree elbow, another elbow and a straight tee. Well, then the ventilation pipe is brought to the roof, where it belongs.


There are a few simple rules drain pipe outlet to the roof:

  1. The drain pipe is installed about half a meter above the roof ridge - but this is only relevant for unused roofs. On the roof, where available summer terrace or a garden, the fan pipe will have to be raised three meters above the roof level.
  2. A sewer system that includes more than one riser is usually connected through a single ventilation pipe.
  3. When calculating the location for the outlet of the exhaust pipe into the atmosphere, you need to select it in such a way that the distance from the nearest windows is at least 4 m.
  4. It is highly undesirable to route the vent pipeline under the eaves of the roof - the design is very high probability will be damaged by precipitation. Read also: "".

Installation of a check valve in a private house

In order for the fan pipeline to function efficiently, it must be additionally equipped with a check valve, which allows you to solve a number of problems:

  • Compensation for errors made during sewer installation in determining the slope of the pipeline, due to which wastewater discharged into the system can return to plumbing fixtures;
  • Preventing various substances from entering the sewer pipeline foreign objects, rodents and other living creatures.


The operation of the check valve comes down to the following points:

  • Wastewater discharged from plumbing fixtures easily enters the system through the automatically opening valve cover;
  • The rest of the time, when the descent Wastewater does not enter the system, the valve is closed;
  • An increase in pressure in the pipeline or its clogging will not cause wastewater to enter the room - in reverse side the valve does not open.

The check valve can be mounted on the external or internal part of the sewer system. Before installing the valve in the system, you must first clean and degrease the pipes so that the element fits well into place.


When the preparation is completed, the valve with the desired side is launched into the system, and its petals are bent towards the plumbing fixtures. When preparing pipes for valve installation, do not use different kinds lubricants - the structure must be dry at the time of installation.

Conclusion

A sewer pipe in a private house allows you to solve a number of problems associated with the operation of the sewer system. Installing a drain pipe and a check valve is not particularly difficult, and if the sewer system was installed with your own hands, then you can install these elements yourself.

In order for the drainage system to work properly, without causing inconvenience in the form of unpleasant odors, plumbing fixtures are equipped with siphons, and the sewerage system itself is equipped with a waste pipe. IN small houses You can do without this design, but sometimes it is still necessary. It is not difficult to equip a fan pipe, but you need to take into account all the requirements for it and the subtleties of installation.

This is a fairly simple device - a separate, usually straight, branch of the sewer pipeline, led vertically upward to the street and connecting the sewage system to the atmosphere.

In cottages with bathrooms on several floors, the drain pipe is a continuation of the riser, leading above the roof. In houses where the drainage system is located on one floor and does not have a riser, the drainage pipe is taken out from one of the sides of the transition unit connecting the internal network to the external one, or from the point of connection to the main line the largest number branches.

Note! The ideal shape of a vent pipe is a vertical straight line, but when installed inside a house, this vertical line will have to intersect the floors and roof, which is not always feasible. To simplify installation work you have to change the shape of the structure: make a 90-degree turn using 2-3 elbow fittings when passing through the wall and direct the pipe upward again.

Purpose of the drain pipe

The vent pipe serves for ventilation sewer network, that is, to remove gases formed in the pipeline and supply fresh air if necessary.

When moving and mixing sewage discharged into a sewage system, various volatile substances are released that have an unpleasant odor and are also hazardous to health.

Installing sewer ventilation solves the problem of gas removal, preventing gases from accumulating in the pipeline.

Note! There is another, more important purpose of the drainage pipe - maintaining the pressure balance in the drainage system.

When flushing water from a bathtub, swimming pool, or using several sinks and toilets at the same time, residents pass a large volume of liquid through the pipeline at once. In this case, the volume of air in the system turns out to be critically small and a vacuum occurs - a decrease in pressure in the network.

Waste systems consist of different types pipelines. One of the main ones is the drainage pipe for sewerage in a private house.

Application

A sewer pipe is a pipeline branch that combines the main riser with an atmospheric pipe or a separate outlet for ventilation of the toilet. This sewer branch is used to protect the home from the penetration of unpleasant sewer odors, as well as to provide sound insulation.

There are metal ones (cast iron is used in apartments, and copper in residential buildings) and plastic (PVC) fan pipes, but plastic is more often used, because its output is more durable and easier to install. Cast iron communications have GOST 6942-98, and plastic communications have GOST 22689.2-89.


The fan pipe can be of any shape and length. She is not prerequisite for arranging a sewer system in a private house with two floors (and one bathroom), but for a small building it will be necessary.

Depending on the type of installation, there are the following types of fan pipes:

  1. Straight;
  2. Angular;
  3. Vertical.

Direct ones are mounted perpendicular to the toilet; they are used in multi-storey buildings and apartments. Corner ones are used for non-standard bathroom layouts, as well as for branching sewer pipes. Vertical are used in two-story houses with several bathrooms. They help eliminate the effect of rarefaction - the disappearance of water from sinks and toilets, which causes wastewater to begin to accumulate.


The purpose of the drain pipe is to constantly monitor the amount of water in the siphons. If liquid disappears from these parts of the sewer drains, an unpleasant odor will fill the building and the pipes will become clogged. The main sewer pipe will stop working.

When to install a drain pipe:


The drain pipe for the toilet is not only additional protection drainage, but also effective sound insulation in multi-storey and private houses. It should be used if the drain blocks the sewer section.


Photo: drain pipe outlet on the roof

Installation

Before installing the fan pipe, it is necessary to calculate its dimensions. For installation corrugated pipe and waste water, an outlet with a diameter of 110 mm is used. This indicator depends on what diameter it has a drain pipe. Most often, the outlet from the toilet is made with a cross-section of 75 mm, but with strong water pressure it can close, which will create some inconvenience. Therefore, for additional protection, a fan pipe of larger diameter is used.


Scheme: fan ventilation

Another serious point of installation is that the drain pipe outlet must be located in a place where sewer odors will be ventilated fresh air. It is advisable to place it in an open space or directly combine it with ventilation ducts.

Video: preparation and installation of cottage sewer pipes

Basic rules for installing a flexible fan ventilation tube:

  1. The section of the fan connection is always larger than the size of the main pipe, otherwise the connection will not be airtight and may break under high pressure of wastewater;
  2. The reinforced sewer pipe should be discharged under a cold, unheated room, and begin in a warm one, this will help organize proper ventilation. At the same time, according to SNiP, attics (because the fan must go down) and street premises are not suitable for installation, since it is necessary to ensure excellent thermal insulation of the pipe;
  3. Most often, one such ventilation system is installed for the entire house. To ensure branching, a special cross is used. Sometimes a tee is used. In some cases, if the building layout is incorrect, it is possible to make several ventilation systems for each bathroom, but then the scheme is developed individually for each.

Once you have decided what vent ventilation and sound insulation are needed for, you need to start installing the pipe. To do this, you first need to prepare the work process. The water in the riser is turned off, and the pipe is cut at the intended location. Depending on the type of ventilation location, you can install the pipeline horizontally or vertically. Horizontal placement will allow not to disturb the beauty of the interior, but it is considered more complex design than vertical.


Diagram: installation of a drain pipe

Afterwards, the communication with the socket is inserted into the prepared main pipeline to a certain depth. Some craftsmen use a detachable fan pipe for ease of installation. Sliding design It is allowed, if necessary, to clean the sewer system.

Regardless of what diameter of the outer or inner vent pipe was chosen, a vacuum check valve must be installed in it.

What it is? The vacuum valve or gasket is used for the following purposes:

  1. Protection of sewage from rodents and other animals;
  2. To prevent waste water from returning. There are quite frequent cases when sewer riser a return line was not installed at all, then in the event of an accident, feces could go back into the home;
  3. If a mixing problem occurs, the valve prevents artificial impurities from returning to the sewer;
  4. With its help, complete sealing of drains is ensured.

Installing a check valve is simple but very important process installation of a sewer system. First, the water in the riser is shut off, the inside of the pipe is completely wiped and degreased with special compounds. It is very important not to lubricate it silicone sealants or adhesives - they can negatively affect the integrity of the valve.

Afterwards, a special insert is inserted into the pipe, which will subsequently serve as the basis for the fan. Then, a vacuum valve is installed. It needs to be snapped into the pipe, but make sure that the petals of the device are open and bent towards the base.

If the knee size is within 110 mm, then you must also use a special adapter. This is a box with additional outlets that will help make a tighter connection between the valve and the main line. Another option for installing the valve is directly into the pipe, then the connection is a cut pipe into which the valve is inserted along with the fan.


You can buy communications at any plumbing store; white fan pipe 75 from brands such as Mcalpine, Jimten, Plastimex, Sanmix, Viega is very popular (the price depends on the size, reinforcement and other characteristics).

Replacement

If the ventilation pipeline was not originally planned for the housing, then it’s okay, it can be completed at any time. But what if it is necessary to replace the drain pipe in the apartment, because it turns out that the connection will be made into the main line?

To begin with, calculate overall size the pipeline is offset; the fan main also has its own slope. If you are replacing an old or leaky pipe, then there will be no problems with selecting the size.


Photo: fan pipes

Step-by-step instruction:

  1. Turn off the water in the riser, check that the main line is closed;
  2. Then cut the pipe into in the right area, disconnect the valve and the fan pipe;
  3. Clean the connection from the inside and replace it with a new one. At the end of the work, be sure to treat the sewer with special sealants over the seam to ensure the tightness of the joint.

At the same time, a ready-made straight vent pipe up to 75 mm can be installed on a roof with a bitumen or corrugated sheet covering on the roof. This is an excellent solution for owners two-story house with several bathrooms. average cost pipeline with a socket of 100 varies from 545 to 700 rubles.

For owners country houses Those who do a lot to improve their home with their own hands, it is useful to know some of the features of arranging water supply and sewer systems. These are the most basic engineering Communication, without which the construction of any house is indispensable.

When installing a sewer system, it is important to remember about such a device as a fan riser. What kind of device is this and what are the nuances of its installation? These and a number of other questions can be answered in our article.

The sewer riser in a private house is a part of the pipeline connecting the sewer riser with access to the open air.

Fan pipe on the roof of a private house

In the absence of this element, during wastewater treatment, a vacuum occurs in the system, the water seal is broken, and an unpleasant odor is felt in the room. Each plumbing fixture must have a drain pipe with an elbow. This bend normally contains water. It acts as a water seal, preventing unpleasant fumes from entering the house. In the event of a sudden discharge of wastewater into sewer pipes discharge occurs. Air from the street passes through the fan device into the system, and the pressure normalizes. This ensures the absence of odors.

Sometimes you can do without a fan boner. For example, in a small building consisting of one or two floors. However mandatory requirement in this case, only one bathroom is equipped.

If the house has two or more bathrooms or several toilets, then installation of a vent riser is mandatory. Its presence is determined by the following factors:


Development stage

Even at the design stage, in order to install the sewer riser correctly, it is necessary to take into account two main requirements:

  1. The sewer pipe must be routed in the direction from which the vapors are removed due to air flows.
  2. In simplified terms, installation of a fan system can be understood as supplying pipes to ventilation duct. If this is difficult to achieve, the outlet is carried out through the wall.

The ventilation structure for eliminating unpleasant odors consists of different parts:

  • fan pipes;
  • ventilation ducts;
  • connecting elements;
  • fittings.

Features of the work

Having understood what a fan riser is, you need to carefully study the principles of its installation. It is advisable to plan the installation of this device as soon as the development of a project for an internal sewer system begins. For ventilation to work better, you need to try to avoid bends and corners in the structure.

Fan riser output diagram

The ideal position of the air riser is exclusively vertical. This pipe is led through the ceilings between floors to the roof. However, this is not always possible to implement in practice. Often in country houses it is necessary to use additional elements for connection.

Sometimes they use the method of connecting several risers into one air duct. This can be the connection of an auxiliary riser to the main one or the removal of a waste pipe with its connection at the same distance from the two risers.

This installation method is better because it allows air pressure to be evenly distributed throughout the system.

Fan pipes on the roof of a building

One of the main rules of installation is the correctly calculated diameter. air pipe. It should not be larger than the diameter of the sewer. Moreover, the indicator of this element ideally corresponds to the size of not only the central riser, but also the pipe, which serves to connect the external and internal sewage systems.

It is also worth remembering that it is unacceptable to combine sewer ventilation with any climate control structure or outlet carbon monoxide when the heating boiler is operating.

How to change a fan riser

If an air riser breaks, it is often necessary to replace it. Replacement of the structure is carried out on the same principle as the repair of individual sections of the sewer system. This process differs mainly in the material from which the pipes are made and the method of connecting them.

Fan pipe repair

To replace the fan riser, a number of conditions must be met:

  1. During dismantling work it is necessary organize good ventilation in the living space.
  2. Structural elements need to be replaced wearing a respirator and rubber gloves.
  3. Upon completion, you need to make sure that all the pipeline remained sealed.

The installation of the fan riser itself is not particularly difficult. Nevertheless, experts recommend following some important requirements.

It is better that the diameters of the fan pipe and the riser coincide.

Fan cast iron pipe

If the work uses a combination of several materials, for example, a plastic drain pipe and a cast iron riser, it is recommended to use a rubber adapter.

To articulate several fans, angles of 45 or 135 degrees are used. Sections of the fan system located horizontally must be laid with a slope of 0.02% in the direction of the gas exit.

If it is necessary to change the angle of direction of the pipe, use a special bend with a rotation degree of 135.

Requirements that fan risers must meet

Certain criteria have been developed for air risers. During installation of the system, it is advisable to check with them:

  1. When the pipe is installed on the roof, it must rise above the roof by at least 30 cm.
  2. If an attic or attic is built The minimum pipe length must be three meters.
  3. The gap between the pipe and a nearby light opening or loggia is made long minimum 4 meters.
  4. Fan system in accordance with existing standards carried out through rooms with heating or must have individual insulation.
  5. It is not allowed to lead the air pipe through the chimney.
  6. The upper component of the vent riser is equipped with a protective grille, which prevents insects and birds from entering the structure.

Common mistakes when installing a riser

Despite the fact that the installation of the fan system can be done independently, there are a number of nuances, knowledge of which will help to avoid serious shortcomings in the installation of the riser.

Installation of a drain pipe

Sometimes incorrectly carried out work on the equipment of the fan structure has quite unpleasant consequences.

For example, owners of country houses do not always install the drain pipe correctly, cutting the system immediately in attic. This leads to unpleasant odors leaking into the attic, which can also penetrate into the home.

Another serious drawback is the installation of a fan according to external wall. In this case, there is a risk of condensation.

Some owners prefer to install an additional device - a roof aerator.

Aerators for pitched roofs

Its function is to improve traction. However, this is not always advisable. In most cases, the following happens: the outflow of sewer gases is weaker and you can feel an unpleasant odor from the bathroom in the house.

Installation of an air riser becomes a prerequisite for proper equipment sewage system. The absence of this device leads to quite negative consequences.

Sometimes it is better to entrust pipe installation to qualified specialists. If you do not have the required number of tools or materials, you should not carry out the installation yourself. There is no point in buying necessary equipment that you are unlikely to need in the future. In addition, the arrangement of sewer systems has its own specifics. An experienced master plumber will do the job efficiently, taking into account all requirements.

In order to carry out the installation correctly, it is necessary to strictly follow the pre-prepared project and perform all the necessary calculations.

How can I replace a fan pipe?

An alternative option for ventilation sewer systems is considered to be vacuum valves. They are installed at the end of the sewer riser in the house itself.

Installing a vacuum valve on a sewer riser

Inside the vacuum-type valve there is a special spring with low resistance and a rubber sealing element for tightness. The operating principle of such a device is as follows:

  1. Sewage, passing along the riser, provides a vacuum in the system.
  2. The shutter or valve opens.
  3. Air from the siphon is sucked in and passes into the sewer network. This extinguishes the vacuum.
  4. After normalizing the pressure in the sewer system, the spring mechanism comes into effect. The valve closes the gap and prevents unpleasant odors from entering the room.

In situations where it is not possible to install a sewer check valve on a riser, this device can be mounted on any other section of horizontal pipe supplied to the riser.

You should also pay attention to this important point, such as the presence of a hydraulic valve at each plumbing point.

Using a hydraulic valve

Otherwise unpleasant odor in the house cannot be avoided, despite the properly installed sewer system and ventilation equipment. In most modern sewerage devices There are built-in hydraulic valves.

There is a special document - a set of Construction Norms and Rules (SNiP). It is necessary to take these requirements into account. The documentation provides the conditions for the mandatory installation of vent risers:

  • houses with two floors or higher, in which there is a sewerage system and installation of plumbing fixtures has been carried out;
  • in houses With autonomous sewerage , with the presence of a storage tank, septic tank or cesspool;
  • if indoors there is a constant unpleasant smell.

In any case, install an air riser in country house necessary. This is the only way to consider the work of laying a sewer system to be done correctly. No one wants to put up with the presence of sewer odors in their living spaces. You can invite professionals to install the fan pipes, or you can try to cope with this task yourself.