» Connection diagram for liquid fuel boiler Kiturami STS 13. Diesel boiler Kiturami. Briefly, the procedure looks like this:

Connection diagram for liquid fuel boiler Kiturami STS 13. Diesel boiler Kiturami. Briefly, the procedure looks like this:

The work of the Kiturami concern is aimed at the production of heating devices using biofuel and gas. But it was the diesel fuel equipment that ensured the popularity of this manufacturer.

Advantages of diesel fuel installations:

  • Ease of use thanks to the ability to control any function using the remote control. The thermostat built into it determines the operating and temperature conditions. The operation of the boiler does not depend on the size and presence of draft, since the existing turbocharging effect contributes to the forced direction of exhaust gases into the chimney;
  • High efficiency is achieved due to aerodynamic flow during fuel combustion;
  • Possibility of self-configuration;
  • Year-round hot water supply;
  • Availability of a self-diagnosis system with information about the operation and malfunctions of the system;
  • Acceptable price;
  • Variety of model range.

The only negative is the type of fuel, which creates a negative environmental situation when burned.


Equipment characteristics

  • The design, equipped with high-quality elements and blocks, differs from other brands. The heat exchanger is made of highly alloyed steel, which has superior physical and technical properties to other metals, which increases its cost, which is compensated by its high quality.
  • The equipment is made of copper, which does not react with water and increases its heat resistance. The presence of internal and external control units, which helps regulate and control the operating mode of the system from different places in the boiler room.
  • Coverage of the power range of floor standing 2-circuit devices – from 10 to 35 kW, sufficient to heat 250-275 sq. m.
  • Dependence of actual fuel consumption on personal settings. An injector from the manufacturer is selected for the actual power parameters.
  • Heating power, fuel consumption and combustion mode are set independently. With power parameters up to 15 kW, the expected fuel consumption is 8 liters per day, while the burner will operate at certain intervals to create the optimal room temperature. By correctly choosing the heating mode and installing a variable temperature controller, you can significantly reduce fuel consumption.
  • Gas, diesel, floor-mounted or wall-mounted boilers are mainly equipped with a combustion chamber closed type and a forced gas exhaust system. Steel or ceramic chimney
  • coaxial so that the supply of street air flow and gas removal are carried out at the same time. It is possible to construct a chimney with a slightly larger diameter - up to 120 mm.

Reducing its size and cross-section is unacceptable.

The lineup The development of KSO models was initially carried out as gas-powered equipment. After changing the type of burner and slightly changing the monitoring and control system, it became possible to use other energy sources. The main thing became diesel fuel . The turbocyclone burner contributed to 100% combustion of fuel and increasing efficiency


. The advantages of the model are simplicity of design, ease of maintenance and low price. Biofuel boilers models KRM-30R and KRM-70R with changes made to their design, they use both diesel fuel and other solid fuel . The transition from one type of fuel to another is carried out quickly. System forced circulation

helps to increase the efficiency of the heater. These models differ only in power. Model turbo 13r generates 13,000 kcal/hour of thermal energy or 15.1 kW, which is enough to heat 150 square meters. m. Taken into account heat costs


for the preparation of hot water supply. With significant regular waste of boiling water, the thermal circuit power is lower. Model turbo 17


has a thermal power parameter of 19.8 kW, sufficient to heat 180 sq. m. To increase the upper performance threshold, nozzles on the burner are selected, which can affect fuel consumption. Model turbo 21r

with a capacity of 24.4 kW it has increased performance of the DHW circuit. At the same time, the dimensions of the boiler remain unchanged. Liquid fuel model turbo 30 r


has a capacity of 34.9 kW, sufficient for heating 350 sq. m. Equipped with torch-shaped burners, the fuel combustion mode is optimal. Due to the low amount of nitrogen oxides, it is a highly environmentally friendly equipment.

  • Price Turbo models 15-35 kW
  • for heating 150-350 sq. m, weighing 52-85 kg - cost 28 thousand-37 thousand rubles; for heating 160-350 sq. m, weighing 40-58 kg - cost 29 thousand-43 thousand rubles;
  • KSO models 58-465 kW for heating 580-4650 sq. m, weighing 93-750 kg - cost 75 thousand-428 thousand rubles.

Owner reviews

“In 2012, a Kiturami 17R boiler was purchased. Great purchase. He was supposed to work as a backup for the Evan Epo-18 electric boiler, acting as the main one in heating system. Since an area of ​​150 square meters was heated. m, then the choice specifically fell on equipment with increased power. IN very coldy the main boiler cannot cope with maintaining the required temperature conditions and stops working due to a drop in voltage in the network. Kiturami acts as a lifeguard, heating and providing water.” Tambov, Arkady

“The Kiturami Turbo boiler is of interest for hot water due to the presence of a SHOWER function, which is capable of producing a small volume hot water over a short period of time." Sochi, Marina

“Wonderful equipment. No matter how many such systems have been installed, practically no one has any complaints. All of Siberia is heated by them.” Ekaterinburg, Sergey

"Already the cost of this equipment capable of interest. Spare parts are always available, the remote controls are unified.” Moscow, Konstantin

“We have our own complaints about the boilers of this company. In my opinion they are not entirely reliable. So we had to resort to repairs twice. Automation can’t handle it.” St. Petersburg, Alexander

Installation and operation rules


If there are voltage surges, it is advisable to purchase a stabilizer to ensure proper operation control and monitoring unit and safety from premature failure

The boilers are equipped with tanks for storing liquid fuel. These tanks may affect the performance of the equipment. Required correct installation this container, which must be aligned in all planes.

The tank must have a pipe for draining sediment and a fixing bag. The container must be periodically emptied of fuel and cleaned; it is recommended to use only purified fuel.

Before starting the equipment, the tank is initially filled with diesel fuel, which must sit for at least half an hour.

Only after this the unit is started and operating modes are adjusted.

In the presence of power surges, it is advisable to purchase a stabilizer to ensure proper operation of the control and monitoring unit and safety from premature failure.

  • To maintain the operation of the boiler you need:
  • Constant monitoring of equipment performance and checking components and parts for leakage.

It is possible to independently install diesel boilers by carefully studying the diagrams and manufacturer’s recommendations. However, there are many operations that require the presence of highly qualified specialists so that the equipment does not have to be repaired later. The instructions for the exact procedure and principle of installation and the electrical installation diagram serve to illustrate the implementation of these works.

Kiturami boilers are an economical option with a long service life. The reason for premature repairs is untimely maintenance or filling with low-quality fuel.

Error codes:

Reasons for lack of ignition - error code “01”:

  • The screw that limits the fuel level is jammed. It is necessary to replace the shut-off element or check the injection motor;
  • Charge motor failure– you will need to check the performance of the motor;
  • Lack of fuel supply– you will need to check its level;
  • Third Party Item in a screw gate;
  • Photosensor failure– it needs to be tested for functionality.

  • Diesel single-circuit and double-circuit models have been developed, the latter are more convenient, but more expensive. If you choose the first option, you will need to purchase a boiler and other appliances and accessories, but its cost will still be lower.
  • It is worth paying attention to the depth of the fuel intake according to the criterion for determining the deep location of the fuel and fuel tank.
  • According to fire safety, fuel tanks must be buried in the ground to an appropriate depth. At low power, the intake depth is higher. The cost of installing the equipment will include the price of the heater

, its installation, commissioning and commissioning work, maintenance and spare parts for its repair. Heating the house in winter period

is a top priority for every homeowner today. This issue is most relevant for owners of suburban housing. And although modern gas boilers are as advanced as possible, they are inaccessible for many people due to the constant increase in the price of this type of fuel. That's why a large number of consumers are chosen by others alternative options

, one of which is the Kiturami diesel boiler. Although they are not new on the market, they have not lost their popularity at all. They are able to provide high-quality heating in the house. Today Kiturami is a well-known South Korean concern, one of the largest manufacturers. The boilers of this company have been repeatedly awarded diplomas for reliability and technical perfection, and due to the presence of certificates that meet all international standards, the Kiturami diesel heating boiler is exported to almost all countries.

What is special about heating equipment from Kiturami?

The Kiturami concern produces different types heating equipment, which includes biofuel and gas installations. But it was Kiturami’s diesel heating equipment that brought the concern such great fame and a high rating. The name diesel itself speaks about the type of fuel on which it runs.

Rice. 1

The most popular model in the line of this manufacturer is the Kiturami Turbo 17 diesel boiler, the purpose of which is hot water supply and heating of industrial and residential premises. Boilers from the manufacturer Kiturami are very convenient for use in country houses, when the need for hot water does not arise daily, and heating is required only when the owners are present there. In addition, with proper operation, repairs of such equipment are very rarely necessary.

The main advantages of Kiturami diesel heating equipment include:

  • The Kiturami diesel boiler is easy to use. The control panel allows you to set any control function. Kiturami's work on coolant and room temperature controlled by a thermostat built into the remote control. The boilers are independent of the size of the chimney and the presence of draft due to their turbo-inflating effect, which forces exhaust gases into the chimney;
  • diesel Kiturami is highly economical. Thanks to the aerodynamic flow in the combustion chamber, maximum efficiency in the amount of fuel consumed is achieved;
  • setting up the equipment is absolutely simple, and you can do it yourself;
  • all year round The house has hot water supply. Kiturami brand boilers are also used when the room is not heated;
  • The Kiturami diesel boiler has a self-diagnosis system, which on the display informs about its operation and any malfunctions that have arisen, showing the real state of the system. If you constantly monitor the display readings, the need for repairs will be minimal.

Features of Kiturami in operation

The diesel heating unit presented by the Kiturami concern differs significantly from other brands in its characteristics, both in the method of maintenance and the need for repairs. Only high alloy steel is used to produce the heat exchanger.


Rice. 2

Kiturami brand boilers are made of copper, which is highly resistant to water. If we talk about price, then in comparison with stainless steel, copper is much cheaper, and, accordingly, a diesel boiler costs accordingly. In addition, copper significantly increases the heat resistance of equipment.

The quality of work of Kiturami Turbo depends on how correctly the containers in which the fuel is stored are placed. Here it is necessary to correctly place the tank and position it on three surfaces. It is imperative to ensure that a drain is provided in the sediment tank. The Turbo reservoir should be cleaned regularly and sediment should be drained, and fuel should be filled into the diesel engine only in purified form. Such treatment contributes uninterrupted operation, and there will be no need for repairs.

When filling a Kiturami diesel boiler with fuel, the instructions say that you need to wait half an hour until it settles. Only after this can the Turbo diesel boiler be started and the required modes adjusted. It is also advisable to use a stabilizer to avoid repairs from sudden changes in voltage in the network. It will ensure stable operation of the control unit and also protect the heating unit from premature repairs.

In order for the Kiturami diesel heating boiler to operate smoothly during operation, the following is necessary:

  • the boiler adjustment must be carried out competently and correctly, then the need for repairs will be minimal;
  • a diesel boiler requires systematic mechanical cleaning in order to protect it from premature repairs;
  • Turbo should be regularly monitored to monitor the operation of all its connections and components for leaks;
  • The performance of the equipment must be checked regularly so that there is no need to repair Kiturami diesel boilers prematurely.

Equipment installation and connection

All the requirements for connecting Kiturami are absolutely not difficult to fulfill on your own. You can install a Kiturami diesel boiler without the help of specialists; all you need to do is carefully study the diagram and recommendations of the manufacturer itself. But at the same time, there are many operations that require the presence of qualified craftsmen in order to subsequently avoid repairs.

For those people who have to assemble Kiturami heating equipment for the first time diesel boilers, the instructions and installation diagram will serve as clear example carrying out such work. It is very important that the Kiturami Turbo connection is made using electrical diagram boiler and all recommendations when connecting to the electrical network were strictly followed.

Anyone who is not sure that they can independently carry out all the work efficiently, on which setting up a Kiturami diesel boiler directly depends, is best to involve specialists, and thus avoid possible errors and premature repairs.

The Kiturami diesel boiler requires an extremely precise procedure and principle for its installation, since an incorrect connection most often causes equipment malfunction and there is a need to carry out expensive repairs of Kiturami diesel boilers.

Description of Kiturami malfunctions and repairs

The Kiturami diesel boiler belongs to the economy version and has a fairly long service life. But there are also situations when boilers fail prematurely. The reason for the need to repair Kiturami is their untimely maintenance or the use of low quality fuel.

You can carry out simple repairs of Turbo boilers yourself, but it is more rational to contact service organizations in case of malfunctions.

Rice. 3 Installed Kiturami boiler

Below are the main error codes that the Kiturami Turbo 17 diesel boiler most often experiences:

  • when the lights flash “01”, “02” or “03” on the display, it means there are problems in the flame detector and ignition does not occur. In this case, the Turbo boiler should be restarted according to the instructions;
  • error “04” indicates that the water temperature sensor is faulty in the Kiturami heating system, and repair in this case becomes inevitable;
  • error "08" warns that the route between the boiler and temperature sensor very long or the wire has broken somewhere. Repairs will be required to identify the immediate cause of the operational failure;
  • error “95” means the pressure in the heating circuit is too low. The Turbo boiler needs to be energized and the entire heating system inspected for possible leaks;
  • error “96” - the mechanism that protects the Turbo system from overheating has activated;
  • error “98” - indicates that there is a lack of fuel in the supply line.

Of all the errors described above, “01” blinks most often on the display, but this does not pose a great danger to the operation of the equipment. The Kiturami Turbo 17 diesel boiler is characterized by maximum efficiency. Thanks to the control panel, the boiler control functionality is achieved and room heating is possible in any temperature regime.

In Turbo it is possible to regulate temperature parameters step by step from 45 to 75°C. All information about the operation of the diesel Kiturami Turbo is displayed on the thermostat screen by a self-diagnosis mechanism.

Most often, the Kiturami diesel boiler produces error 01. This happens when there is no stable ignition in the Turbo.

The reasons may be as follows:

  • when the screw jams, which serves as a fuel level limiter. The repair consists of replacing the locking element or checking the injection motor;
  • when the injection motor fails. It is necessary to check the working condition of the Kiturami motor. If the motor is faulty, then the repair consists of replacing it with a new one;
  • when there is not enough incoming fuel, then the level in the tank should be checked; repairs in this case will not be necessary;
  • when a foreign object accidentally ends up in the screw gate, it must be removed during the repair process;
  • when the photosensor fails, the Turbo repair consists of checking this element for its functionality.

When error code “01” periodically appears on the display, in such cases it is necessary to seek help from the appropriate specialists in order to avoid major expensive repairs.

Carrying out regular maintenance and repairs of Kiturami is a guarantee that Turbo boilers will operate efficiently and reliably. If irreparable damage occurs to a diesel boiler during the warranty period, it will be repaired without the need to pay for such work.

The Kiturami Turbo diesel boiler has excellent characteristics, but you must always remember that non-compliance established scheme installations, correct settings and basic rules for handling it in many cases ends in total repairs. When all requirements for use and operation are met modern technologies production of heating equipment Kiturami guarantees each user stable operation of the boiler without the need for repairs and a long service life.

Even at the stage of designing heating in a house, one has to operate with generalized technical characteristics boiler, but in the end you still need to go to the store and choose a very specific model from the huge assortment on the market.

It will be useful to find out in more detail what a Kiturami diesel boiler is, what models are in the line, and how they can be better than other offers on the market.

Features of Kiturami boilers

Kiturami is a South Korean company with more than half a century of experience in the development and production of heating boilers and related equipment.

During this time, the company became one of the leaders in the domestic Korean market, and also found an extensive market in North America and nearby Asian countries. In our country, Kiturami boilers have been officially distributed for at least ten years and have already managed to show their good side.

The main emphasis in promoting boilers is on the implementation innovative technologies and in particular, our own developments, which have no analogues from other manufacturers or determine the narrow specificity of the equipment’s operation.

Diesel boilers, by definition, are not considered as the main the lineup For wide range applications. In respect of economic feasibility they are inferior to gas, electric and even solid-state boilers. However, they are still in demand among consumers due to a number of reasons why liquid fuel is becoming preferable.


In remote areas of residence, where there is no stable connection to power grids and no gas supply, the issue of fuel availability becomes acute. At the same time, the heating of the house must, by definition, work uninterruptedly throughout the entire season. If for many countries similar situations Rather an exception to the rule, for us, on the contrary, it is commonplace, the reason for which is the vast expanses that separate populated areas.

Diesel fuel, unlike gas, is easier to transport and easier to store with minimal risks to life and environment. Unlike solid fuel boilers, diesel fuel, when burned, provides uniform heating and a greater degree of control over resource consumption. And finally, the design of a diesel boiler and, in particular, the burner does not limit the use of other heat sources.

With minimal changes, a diesel burner can be replaced to use blue fuel, and boilers equipped with an extensive combustion chamber and grate can can quickly switch to using coal, wood or pellets.

Kiturami diesel boilers are highly technologically advanced and are ideally balanced equipment for using diesel fuel as a heat source, and at the same time they are excellent for listed types conversions for operation on gas or solid fuel. So constructive and functional flexibility is the first significant advantage.

Kiturami boilers often use their own developments and a unique layout. On the one hand, this reduces the maintainability of heating equipment, but on the other hand, it provides the most high efficiency boiler and balanced operation while observing simple and transparent operating rules. This is the second good reason to turn our attention to diesel boilers from South Korea.

The last advantage is the cost of boiler equipment. Even taking into account the high performance and proven quality of the boilers, their cost does not exceed the market average among similar offers.

So it turns out that Kiturami boilers have three features: a balanced design, high efficiency And affordable price.


Kiturami boiler design

Specifications

The operational characteristics, dimensions and parameters of Turbo series boilers are presented in the table below. It is clearly seen that the series of floor-standing diesel boilers covers a power range from 10 to 35 kW, which is quite enough to heat houses up to 250-275 square meters. Part of the heat will be used to prepare hot water, which must be taken into account in the calculations.

All Kuturami double-circuit boilers and heat exchangers, by the way, are ideally designed specifically for these tasks.

Boiler modelUnit changeTURBO-9RTURBO-13RTURBO-17RTURBO-21RTURBO-30R
Powerkcal/hour9000 13000 17000 21000 30000
PowerkW10,5 15,1 19,8 24,4 34,9
Fuel consumptionliter/hour1.13÷1.51.6÷1.971.87÷2.152.28÷2.803.75÷4.30
Efficiency% 92 92 92.2 92.4 91.8
DHW consumptionΔt=25ºC6,0 9,7 11,3 14,0 23,3
Δt=40ºC3,8 6,1 7,1 8,7 14,6
Heating supply and returnmm25 25 25 25 25
Hot water inlet/outletmm15 15 15 15 15
Chimney diametermm80
Power supplyV/Hz220/50(60)
Energy consumptionW80 160
External sizew×d×h325×600×835365×650×930
Weightkg60 79 85 85 85

Fuel consumption

Fuel consumption is shown in the table with technical requirements. However, please remember that actual consumption depends on individual settings. Based on the actual power required to heat the house, an appropriate nozzle is selected from the set offered by the manufacturer.

Thermal power, fuel consumption and fuel combustion mode are set. The parameter indicated in the table displays factory presets sufficient to ensure proper performance provided that only high-quality fuel is used, more often this means diesel fuel with winter additives that do not allow it to thicken or separate paraffin in excess of the norm.

In a real situation, for a boiler model with a power of up to 15 kW, you can expect fuel consumption at 8 liters per day taking into account the frequency of burner operation and the optimal temperature conditions in the house. However, this is not the limit.

The correct approach to choosing a heating mode, as well as installing a controller with variable temperature conditions, for example, depending on the time of day and day of the week, can reduce consumption even further.

Chimney

Cuturami boilers, gas, diesel, floor-mounted or wall-mounted, are mostly equipped with a closed combustion chamber and, accordingly, compulsory system exhaust gas removal. The Turbo series we are currently reviewing is no exception.


Chimney installation diagram

The chimney for boilers is coaxial for simultaneous supply fresh air from the street and exhaust gas removal. Since the exhaust temperature after passing through the heat exchangers is no longer high, the requirements for the heat resistance of the chimney are reduced, and the list of acceptable materials is expanded.

At best, steel is still used coaxial chimney, however, a ceramic vertical chimney with a group of internal separate channels for supplying air, removing gases from the combustion chamber and ventilating the boiler room can be effectively used in the same capacity.

The size of the chimney is strictly indicated in the boiler specification and operating instructions. For the entire Turbo series it is 80 mm.

If desired, you can make a chimney with a slightly larger diameter, but no more than 50% above the specified value, that is, up to 120 mm.

Under no circumstances should the size and cross-section be reduced. Even though the removal of combustion products is forced, the resistance of the chimney will greatly affect the combustion mode and the quality of fuel combustion.

turbo 13r

The boiler model number corresponds to the amount of heat generated per hour - 13,000 kcal/hour. Converted to conventional kilowatts, the resulting value is 15.1 kW.

The declared power is enough to heat a house with an area of ​​up to 150 m2. Naturally, one should take into account the heat costs for preparing hot water. If a significant consumption of hot water is predicted, and regularly, then the thermal power for the heating circuit will naturally be lower.

Reliability and balanced operation, combined with the affordable cost of the boiler, gives a clear advantage in the case of using several boilers simultaneously in one building, for example, when dividing the heating circuit for each floor separately or when covering a large area in two more directions.

turbo 17


Boiler Kiturami turbo

Thermal power already reaches 19.8 kW, which is enough to cover the heating of a house with an area of ​​up to 180 m2. It is possible to increase within reasonable limits upper threshold performance by selecting the appropriate nozzle on the burner, however, this will affect fuel consumption.

This approach allows you to solve the problem with increased DHW consumption so that without extra costs do not hesitate to use hot water even in the most severe frosts.

turbo 21r

With a further increase in power comes a model with a declared performance of 24.4 kW, and at the same time the performance of the DHW circuit increases significantly. It should be noted that the dimensions of the boiler do not change compared to younger models.

turbo 30r

The most powerful model in the Kiturami line of liquid fuel boilers. A performance of 34.9 kW makes it possible to heat a room up to 350 m2, but at the same time The cost of the boiler at retail is approximately 45-46 thousand rubles., which is undoubtedly an attractive option.

As with the entire line of boilers, burners with a unique flame shape and optimal mode fuel combustion.

A minimum amount of nitrogen oxides is recorded in the exhaust, which indicates the high environmental friendliness of the equipment.

Settings

It is better to entrust the initial startup and setup of Kiturami boilers to a specialist who can correctly determine the optimal operating mode and select desired type injectors and check the fuel consumption depending on its characteristics and even the method of connection and location of the fuel tank.

Nozzle for diesel boiler

For self-installation The boiler comes with detailed instructions, according to which you can determine the operating mode closest to the design value.

The main thing is to adhere to the sequence of actions defined in technical documentation and a visual aid for putting the equipment into operation.

Setting up and adjusting the boiler settings should be carried out not only at the first start-up, but also during maintenance before each new season and to switch to summer mode, in which only the DHW circuit will be used.

Malfunctions

Kuturami boiler equipment is equipped with a full-fledged self-diagnosis system based on the operation of a number of sensors. The controller is able to assess the condition of the equipment, as well as the current operating mode, and respond to any deviations or problems that arise during operation.

In any emergency situation, the main action assigned to the boiler controller is to stop the burner to prevent significant consequences.

A well-developed self-diagnosis algorithm allows you to identify the problem and indicate the error code on the display so that the user can take action as quickly as possible necessary actions for repair and restoration of functionality.

Among frequent breakdowns Kiturami diesel boilers:

  • No ignition (error code 01);
  • Does not start, there are no messages on the display.;
  • Coolant leakage (depressurization of the heat exchanger or one of the pipeline connections);
  • The flame goes out periodically emergency stop boiler;
  • There is no draft, the operation of the boiler is accompanied by the flow of smoke and exhaust into the room.

Error 01 and solution

If error code 01 appears on the boiler display screen, it means that for some reason the fuel did not ignite, there is no torch, the controller forcibly stops the fuel supply, displays an error message, and signals the problem to the user.

Solving the problem requires precise execution of a procedure that can identify the source of the problem and eliminate the obstacle in the operation of the boiler as effectively as possible.

IN in brief the procedure looks like this:


Quite often, the fuel-air mixture is supplied under too much pressure into the chamber and therefore does not have time to ignite from the electrode. The problem is solved at the 5th step of the algorithm by adjusting the air damper, which causes a mixture with a changed concentration to enter the chamber.

Doesn't start

The most unpleasant situation is when the boiler simply does not turn on. There are no signals on the display, and accordingly there is no error code by which the malfunction can be determined.

In such a situation, it would be appropriate to call a specialist service center, who will be able to understand the situation and give the correct verdict, as well as determine the repair procedure. You can independently only check the presence of voltage in the network, as well as the fuses in the boiler.

Leak

Most often, a leak means that the seal has been damaged in some connection of the pipeline inside the boiler. It is enough to inspect the equipment and determine the location of the leak and replace the gasket.

The heat exchanger in Kiturami boilers is made of alloy steel and copper, so it does not leak without obvious errors in the selection of coolant or mechanical damage.

Burner goes out periodically

Most common cause is a malfunction in the burner settings. It is important to adjust its power and use a gas analyzer to determine optimal ratio air/fuel for complete combustion. You cannot do such work yourself, so it is better to contact a service center.

There is no draft, smoke and exhaust enters the room

Most likely, the burner fan is not working for some reason. It is important to first check that the impeller is intact and rotates normally.

It is possible that debris has accumulated inside the fan, or the impeller shaft is jammed. Next it is checked electrical part and control unit.

Kiturami boiler piping is a set of measures related to connecting boiler equipment to power supply, water supply, heating systems, fuel lines and smoke exhaust systems. It is advisable to piping the boiler with the help of qualified specialists and in accordance with the instructions specified in the quality certificate.

Electrical connection

Boiler equipment operates when powered by a 220V network. When connecting the boiler to the power supply system, the following recommendations must be observed:

1 - to prevent accidents, electric shock or short circuit caused by electrical leakage in the boiler, grounding is necessary. The grounding point must be at a depth of at least 300 mm.

2 – it is necessary to have a separate socket designed specifically for connecting the boiler. This socket must be installed at a distance of at least 300 mm from the boiler equipment.

3 – it is desirable to include a stabilizing device in the power supply system.

In picture No. 1 depicted standard system connection to the electrical network.

Connection to heating systems, water supply and fuel lines

1 - when connecting to a heating system, it is necessary to install shut-off valves, filters and additional expansion tanks that will compensate for the expansion of the coolant.

2 – when connecting to a hot water supply system, it is also necessary to install shut-off valves, filters and expansion tanks. When using low-quality water, it is recommended to install a water treatment system, which will increase the service life of the boiler and ensure reliable operation of mixing devices.

3 – when connecting to a pipeline, in addition to installing filters and shut-off valves, it is recommended to install pressure reducers designed to protect the boiler from excessive pressure in the main pipeline. When the pressure in the main pipeline is low, it is recommended to install pressure boosting stations.

4 – when connecting to a fuel pipeline, it is necessary to install additional filters and shut-off valves.

In picture No. 2 shows the standard piping system (piping in the downward direction) for the Kiturami Turbo boiler.

Installation of a smoke removal system.

When piping the boiler with a smoke removal system, it is necessary to install ventilation pipes with the required angle of inclination from the boiler in order to prevent condensate from entering the combustion chamber, fan and smoke exhauster, which can lead to damage to these elements.

In picture No. 3 given standard scheme chimney installation

1 – installation diagram in the presence of a chimney

2 – installation diagram in the absence of a chimney.

1 – the chimney must be installed in such a way as to avoid the wind pressure zone in the upper part of the pipe, to protect the pipe from precipitation. Installing a chimney in a wind pressure zone leads to a decrease in boiler efficiency and can cause emergency shutdowns.

2 – if within 1 m from the chimney there is high building, you need to install chimney higher than this building by at least 1 m. More detailed instructions and requirements for piping boilers are given in the operating manuals that are attached to the boiler equipment when it is sold.

Compliance with all the requirements specified in the accompanying documentation will avoid problems during operation of the boiler, increase its service life and your safety.